Images:

SNZB-02 Capteur de température / humidité

Nom : SNZB-02 Capteur de température / humidité
Marque : sonoff
  panier-acheter-ecommerce-shopping-icone-8314-48
Description:

Appairage

Pour mettre cet objet en mode inclusion, il faut :

Appuyer 10 sec sur le bouton du dessus

TRACES

Type: 0x004D (End Device Announce)
Short Address: 0x18B4
Extended Address: 0x124B001B7819C6
MAC Capability: 0x80
Alternate PAN Coordinator: False
Device Type: End Device
Power Source: Battery
Receiver On When Idle: False
Security Capability: Standard
Allocate Address: True

Type: 0x8045 (Active Endpoints Response)
SQN: 0x32
Status: 0x00
Short Address: 0x18B4
Endpoint Count: 1
Endpoint List:
Endpoint 0: 0x01

Type: 0x8043 (Simple Descriptor Response)
SQN: 0x33
Status: 0x00
Short Address: 0x18B4
Length: 20
EndPoint: 0x01
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0302 (Unknown)
Input Cluster Count: 5
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0003 (General: Identify)
Cluster 2: Cluster ID: 0x0402 (Measurement: Temperature)
Cluster 3: Cluster ID: 0x0405 (Unknown)
Cluster 4: Cluster ID: 0x0001 (General: Power Config)
Output Cluster Count: 1
Cluster 0: Cluster ID: 0x0003 (General: Identify)

Type: 0x8102 (Attribute Report)
SQN: 0x05
Src Addr: 0x18B4
Src Ep: 0x01
Cluster ID: 0x0000 (General: Basic)
Attribute ID: 0x0005
Attribute Size: 0x0004
Attribute Type: 0x42 (Character String)
Attribute Data (Len – 4): TH01
Status: 0x00

Astuces :

Faire un BIND sur les clusters :
– 0x0001 : power config
– 0x0402 : temperature
– 0x0405 : humidité

puis

Faire un CONFIGURE REPORT sur
– 0x0402 : temperature
– 0x0405 : humidité

Back