Images:

Telecommande simple Profalux

Nom : Telecommande simple Profalux
Marque : Profalux
 
Description:

Clusters disponibles

  EndPoint: 0x01
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0200 (Unknown)
Input Cluster Count: 11
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0003 (General: Identify)
Cluster 2: Cluster ID: 0x0004 (General: Groups)
Cluster 3: Cluster ID: 0x0005 (General: Scenes)
Cluster 4: Cluster ID: 0x0006 (General: On/Off)
Cluster 5: Cluster ID: 0x0008 (General: Level Control)
Cluster 6: Cluster ID: 0x000A (General: Time)
Cluster 7: Cluster ID: 0x0015 (Unknown)
Cluster 8: Cluster ID: 0x0100 (Unknown)
Cluster 9: Cluster ID: 0xFC20 (Unknown)
Cluster 10: Cluster ID: 0xFC21 (Unknown)
Output Cluster Count: 2
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0003 (General: Identify)

Suivre les instructions suivantes pour l’appairage :

Association des volets Profalux à la ZiGate

Device announce du volet

ZiGate ← 01 00 4D 00 0C 7D 60 ED 00 0D 6F 00 0D EC BD C7 8E C6 03

Décodage :

Type: 0x004D (End Device Announce)
Short Address: 0x60ED
Extended Address: 0xD6F000DECBDC7
MAC Capability: 0x8E
Alternate PAN Coordinator: False
Device Type: Router
Power Source: AC
Receiver On When Idle: True
Security Capability: Standard
Allocate Address: True

Route Discovery Confirm

ZiGate ← 01 87 01 00 03 49 00 00 CC 03

Décodage :

Type: 0x8701 (Route Discovery Confirm)
SQN: 0x00
Status: 0x00
Network Status: 0xCC

Device announce de la télécommande maître

ZiGate ← 01 00 4D 00 0C BB AD 62 00 0D 6F 00 05 B9 E4 43 80 CC 03

Décodage :

Type: 0x004D (End Device Announce)
Short Address: 0xAD62
Extended Address: 0xD6F0005B9E443
MAC Capability: 0x80
Alternate PAN Coordinator: False
Device Type: End Device
Power Source: Battery
Receiver On When Idle: False
Security Capability: Standard
Allocate Address: True

Route Discovery Confirm

ZiGate ← 01 87 01 00 03 31 00 00 B4 03

Décodage :

Type: 0x8701 (Route Discovery Confirm)
SQN: 0x00
Status: 0x00
Network Status: 0xB4

Commandes

OFF

Requête :

ZiGate -> 01 02 10 92 02 10 02 16 1B 02 12 60 ED 02 11 02 11 02 10 03 (ON/OFF Cluster request)

Réponse :

ZiGate <- 01 80 00 00 05 1B 00 0C 00 92 00 03(Status succès)

ZiGate <-  01 81 01 00 07 40 0C 01 00 06 00 00 CC 03

Décodage :

Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x0C
Message:
Type: 0x8101 (Default Response)
SQN: 0x0C
EndPoint: 0x01
Cluster ID: 0x0006 (General: On/Off)
Command: 0x00
Status: 0x00

ON

Requête :

ZiGate -> 01 02 10 92 02 10 02 16 1A 02 12 60 ED 02 11 02 11 02 11 03 (ON/OFF Cluster request)

Réponse :

ZiGate <- 01 80 00 00 05 1A 00 0D 00 92 00 03 (Status succès)

ZiGate <- 01 81 01 00 07 3B 0D 01 00 06 01 00 B7 03

Décodage :

Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x0D
Message:
Type: 0x8101 (Default Response)
SQN: 0x0D
EndPoint: 0x01
Cluster ID: 0x0006 (General: On/Off)
Command: 0x01
Status: 0x00

TOGGLE

Requête :

ZiGate -> 01 02 10 92 02 10 02 16 19 02 12 60 ED 02 11 02 11 02 12 03 (ON/OFF Cluster request)

Réponse :

ZiGate <- 01 80 00 00 05 19 00 0E 00 92 00 03 (Status succès)

ZiGate <- 01 81 01 00 07 40 0E 01 00 06 02 00 CC 03

Décodage :

Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x0E
Message:
Type: 0x8101 (Default Response)
SQN: 0x0E
EndPoint: 0x01
Cluster ID: 0x0006 (General: On/Off)
Command: 0x02
Status: 0x00

Level Control

Requête :

ZiGate -> 01 02 10 81 02 10 02 19 02 16 02 12 60 ED 02 11 02 11 02 10 02 10 02 10 02 11 03 ( 0x0081 Move to level with/without on/off)

with/without on off

Level -> 0 …255 (niveau de fermeture du volet)

Time transition

Réponse :

ZiGate <- 01 80 00 00 05 14 00 10 00 81 00 03 (Status succès)

ZiGate <- 01 81 01 00 07 2A 10 01 00 08 00 00 B4 03

Back

Translate »