Images:

Osram switch mini

Nom : Osram switch mini
Marque : OSRAM
  panier-acheter-ecommerce-shopping-icone-8314-48
Description:

Appairage –> Fleche vers le haut + 0 —10 sec
Reset -> 0 + fleche vers bas —10 sec
touchlink –> les deux fleches —10 sec

TRACES

Active Endpoints

Type: 0x004D (End Device Announce)
Short Address: 0x8BB3
Extended Address: 0xD6F00101CF754
MAC Capability: 0x80
Alternate PAN Coordinator: False
Device Type: End Device
Power Source: Battery
Receiver On When Idle: False
Security Capability: Standard
Allocate Address: True

Type: 0x8045 (Active Endpoints Response)
SQN: 0x99
Status: 0x00
Short Address: 0x8BB3
Endpoint Count: 3
Endpoint List:
Endpoint 0: 0x01
Endpoint 1: 0x02
Endpoint 2: 0x03

Type: 0x8043 (Simple Descriptor Response)
SQN: 0x9A
Status: 0x00
Short Address: 0x8BB3
Length: 34
EndPoint: 0x01
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 5
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0001 (General: Power Config)
Cluster 2: Cluster ID: 0x0020 (General: Poll Control)
Cluster 3: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 4: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 8
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0019 (General: OTA)
Cluster 6: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 7: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0x9B
Status: 0x00
Short Address: 0x8BB3
Length: 28
EndPoint: 0x02
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0x9C
Status: 0x00
Short Address: 0x8BB3
Length: 28
EndPoint: 0x03
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Appairage –> Fleche vers le haut + 0 —10 sec
Reset -> 0 + fleche vers bas —10 sec
touchlink –> les deux fleches —10 sec

Back