Images:

Osram Lightify Interrupteur Télécommande Gris

Nom : Osram Lightify Interrupteur Télécommande Gris
Marque : OSRAM
  panier-acheter-ecommerce-shopping-icone-8314-48
Description:

Cet interrupteur a la particularité d’envoyer tous ces messages au « endpoint de destination » 0xFF

Chaque fonction de bouton correspond à un « endpoint source » différent (voir ACTIVE ENDPOINT)

 

TRACES

Active Endpoints

Type: 0x8045 (Active Endpoints Response)
SQN: 0x9F
Status: 0x00
Short Address: 0x00DF
Endpoint Count: 6
Endpoint List:
Endpoint 0: 0x01
Endpoint 1: 0x02
Endpoint 2: 0x03
Endpoint 3: 0x04
Endpoint 4: 0x05
Endpoint 5: 0x06

Clusters

Type: 0x8043 (Simple Descriptor Response)
SQN: 0xA0
Status: 0x00
Short Address: 0x00DF
Length: 34
EndPoint: 0x01
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 5
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0001 (General: Power Config)
Cluster 2: Cluster ID: 0x0020 (General: Poll Control)
Cluster 3: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 4: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 8
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0019 (General: OTA)
Cluster 6: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 7: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0xA1
Status: 0x00
Short Address: 0x00DF
Length: 28
EndPoint: 0x02
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0xA2
Status: 0x00
Short Address: 0x00DF
Length: 28
EndPoint: 0x03
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0xA3
Status: 0x00
Short Address: 0x00DF
Length: 28
EndPoint: 0x04
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0xA4
Status: 0x00
Short Address: 0x00DF
Length: 28
EndPoint: 0x05
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Type: 0x8043 (Simple Descriptor Response)
SQN: 0xA5
Status: 0x00
Short Address: 0x00DF
Length: 28
EndPoint: 0x06
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0810 (Unknown)
Input Cluster Count: 3
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x1000 (ZLL: Commissioning)
Cluster 2: Cluster ID: 0xFD00 (Unknown)
Output Cluster Count: 7
Cluster 0: Cluster ID: 0x0003 (General: Identify)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0005 (General: Scenes)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0300 (Lighting: Color Control)
Cluster 6: Cluster ID: 0x1000 (ZLL: Commissioning)

Back