La ZiGate est une passerelle entre les objets communiquant en ZigBee® et votre box domotique. L’objectif principal de la ZiGate est de ne pas s’attacher à un protocole ZigBee® en particulier. En effet, le souhait est de mutualiser le plus de matériels possibles car mêler plusieurs marques pour sa domotique est un gage de liberté. ZiGate dit stop aux monopoles techniques.

Voici la liste des matériels compatibles :

 

Images:

iHorn Capteur temperature humidite

Nom : iHorn Capteur temperature humidite
Marque : IHorn
  panier-acheter-ecommerce-shopping-icone-8314-48
Description:

Appairage

Il faut ouvrir le boitier pile et appuyer 10 secondes sur le  bouton

TRACES

Type: 0x004D (End Device Announce)
Short Address: 0x69C2
Extended Address: 0x158D00040FEADD
MAC Capability: 0x80
Alternate PAN Coordinator: False
Device Type: End Device
Power Source: Battery
Receiver On When Idle: False
Security Capability: Standard
Allocate Address: True

Type: 0x8045 (Active Endpoints Response)
SQN: 0x4E
Status: 0x00
Short Address: 0x69C2
Endpoint Count: 1
Endpoint List:
Endpoint 0: 0x01

Type: 0x8043 (Simple Descriptor Response)
SQN: 0x4F
Status: 0x00
Short Address: 0x69C2
Length: 48
EndPoint: 0x01
Profile ID: 0x0104 (ZigBee HA)
Device ID: 0x0302 (Unknown)
Input Cluster Count: 9
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0003 (General: Identify)
Cluster 2: Cluster ID: 0x0402 (Measurement: Temperature)
Cluster 3: Cluster ID: 0x0405 (Unknown)
Cluster 4: Cluster ID: 0x0019 (General: OTA)
Cluster 5: Cluster ID: 0x0500 (Security & Safety: IAS Zone)
Cluster 6: Cluster ID: 0x0B05 (Misc: Diagnostics)
Cluster 7: Cluster ID: 0x0000 (General: Basic)
Cluster 8: Cluster ID: 0x0001 (General: Power Config)
Output Cluster Count: 11
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0405 (Unknown)
Cluster 3: Cluster ID: 0x0003 (General: Identify)
Cluster 4: Cluster ID: 0x0402 (Measurement: Temperature)
Cluster 5: Cluster ID: 0x0500 (Security & Safety: IAS Zone)
Cluster 6: Cluster ID: 0x0006 (General: On/Off)
Cluster 7: Cluster ID: 0x0008 (General: Level Control)
Cluster 8: Cluster ID: 0x0005 (General: Scenes)
Cluster 9: Cluster ID: 0x0019 (General: OTA)
Cluster 10: Cluster ID: 0x0001 (General: Power Config)

Type: 0x8102 (Attribute Report)
SQN: 0x10
Src Addr: 0x69C2
Src Ep: 0x01
Cluster ID: 0x0000 (General: Basic)
Attribute ID: 0x0005
Attribute Size: 0x0004
Attribute Type: 0x42 (Character String)
Attribute Data (Len – 4): 113D
Status: 0x00

 