Instructions pour les ampoules INNR
Clusters disponibles
EndPoint: 0x01
Profile ID: 0xC05E (ZigBee LL)
Device ID: 0x0100 (Lighting – On/Off Light)
Input Cluster Count: 6
Cluster 0: Cluster ID: 0x0000 (General: Basic)
Cluster 1: Cluster ID: 0x0004 (General: Groups)
Cluster 2: Cluster ID: 0x0003 (General: Identify)
Cluster 3: Cluster ID: 0x0006 (General: On/Off)
Cluster 4: Cluster ID: 0x0008 (General: Level Control)
Cluster 5: Cluster ID: 0x0005 (General: Scenes)
Output Cluster Count: 1
Cluster 0: Cluster ID: 0x0000 (General: Basic)
EndPoint: 0x02
Profile ID: 0xC05E (ZigBee LL)
Device ID: 0x1000 (Unknown)
Input Cluster Count: 1
Cluster 0: Cluster ID: 0x1000 (ZLL: Commissioning)
Output Cluster Count: 0
Suivre la procédure pour mettre la ZiGate en mode « écoute » :
Suivre les procédures pour faire un « Factory reset » de l’ampoule.
Device announce
ZiGate ← 01 00 4D 00 0C AC 96 0B 00 15 8D 00 01 74 22 8C 8E BD 03
Header
01 = Start
00 4D = Message type (device announce)
00 0C = Taille message
AC = Checksum
Message (Device announce):
96 0B= Short address ( adresse utilisée dans le réseau)
00 15 8D 00 01 74 22 8C = Adresse MAC IEEE
8E = Mac capability
Footer
BD = Qualité du signal
03 = End
Décodage :
Type: 0x004D (End Device Announce)
Short Address: 0x960B
Extended Address: 0x158D000174228C
MAC Capability: 0x8E
Alternate PAN Coordinator: False
Device Type: Router
Power Source: AC
Receiver On When Idle: True
Security Capability: Standard
Allocate Address: True
Route Discovery Confirm
ZiGate ← 01 87 01 00 03 38 00 00 BD 03
Décodage :
Type: 0x8701 (Route Discovery Confirm)
SQN: 0x00
Status: 0x00
Network Status: 0xBD
Commandes
Lumière ON
Requête :
ZiGate -> 01 02 10 92 02 10 02 16 02 1A 02 12 96 02 1B 02 11 02 11 02 11 03 (ON/OFF Cluster request)
Réponse :
ZiGate <- 01 80 00 00 05 04 00 13 00 92 00 03(Status succès)
ZiGate <- 01 81 01 00 07 3A 13 01 00 06 01 00 A8 03
Décodage :
Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x13
Message:
Type: 0x8101 (Default Response)
SQN: 0x13
EndPoint: 0x01
Cluster ID: 0x0006 (General: On/Off)
Command: 0x01
Status: 0x00
Lumière OFF
Requête :
ZiGate -> 01 02 10 92 02 10 02 16 02 1B 02 12 96 02 1B 02 11 02 11 02 10 03 (ON/OFF Cluster request)
Réponse :
ZiGate <- 01 80 00 00 05 03 00 14 00 92 00 03 (Status succès)
ZiGate <- 01 81 01 00 07 0B 14 01 00 06 00 00 9F 03
Décodage :
Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x14
Message:
Type: 0x8101 (Default Response)
SQN: 0x14
EndPoint: 0x01
Cluster ID: 0x0006 (General: On/Off)
Command: 0x00
Status: 0x00
Lumière TOGGLE
Requête :
ZiGate -> 01 02 10 92 02 10 02 16 02 19 02 12 96 02 1B 02 11 02 11 02 12 03 (ON/OFF Cluster request)
Réponse :
ZiGate <- 01 80 00 00 05 02 00 15 00 92 00 03 (Status succès)
ZiGate <- 01 81 01 00 07 08 15 01 00 06 02 00 9F 03
Décodage :
Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x15
Message:
Type: 0x8101 (Default Response)
SQN: 0x15
EndPoint: 0x01
Cluster ID: 0x0006 (General: On/Off)
Command: 0x02
Status: 0x00
Variation de Lumière (Move to Level)
Requête :
ZiGate -> 01 02 10 81 02 10 02 19 47 02 12 96 02 1B 02 11 02 11 02 11 50 02 10 02 11 03 (MoveToLevel Cluster request)
Réponse :
ZiGate <- 01 80 00 00 05 13 00 17 00 81 00 03 (Status succès)
ZiGate <- 01 81 01 00 07 35 17 01 00 08 04 00 A8 03
Décodage :
Type: 0x8000 (Status)
Length: 5
Status: 0x00 (Success)
SQN: 0x17
Message:
Type: 0x8101 (Default Response)
SQN: 0x17
EndPoint: 0x01
Cluster ID: 0x0008 (General: Level Control)
Command: 0x04
Status: 0x00